Say something interesting about your business here.
What's something exciting your business offers? Say it here.
The Lift by Jane Mann program 1 is used for connective tissue. It has four different cycles that run approximately 6 minutes and repeat. The program time is 1 hour.
Use program 1 first on the client. Many times I like to apply a peptide or stem cell product to increase cellular responsiveness. You can also do after using LED. The purpose of P1 is to increase cellular hydration, hydration of the tissues as well as initiating cellular protein synthesis. (This is not unique to the LBJM unit however. Microcurrent has been proven to do this.) However, program 1 is dedicated to more of a skin level to induce the production collagen and elastin.This program should be done first to create circulation and hydration of the cells.
Every client responds differently to an electric facial. Some clients prefer a tiny sensation, while others are happy with feeling nothing. The rule of thumb of microcurrent is one should not feel anything.
Guidelines to follow:
Thin skin with little to no circulation 5-30
Thin skin with an impaired barrier 5-15
Medium skin with little to no circulation 30-55
Medium skin that is oily 30-75
Medium skin that is dehydrated and show signs of photo damage 30-55
Thick skin or face that has a thick subcutaneous fat layer 40-65
Thick skin that is oily 40-75
Thick photo damaged skin 50-75
Program 2 is dedicated to toning the muscles and can also be used for lymphatic drainage. There are 4 cycles with in the program. Each one last approximately 6 minutes and then repeat for 1 hour. These patterns or waveforms navigate the impedance of the skin to reach the motor neuron of the sarcomere. The end result are action potentials with in the muscles fibers that demand the mitochondria make more ATP to support the tiny muscular contractions.
I use program 2, after program 1, or sometimes just as a quick demo to sell a service in the treatment. I always use P2 with the LIFT microcurrent probe, because when working on a the muscles it is important that you have the positive and negative sides only 1 to 1.5 inches apart. This distance is optimal for the magnetic pull of the ions to generate an action potential in the muscles fibers. When you use the lift probe is will fit all unique angles and sizes of the face. However the unit will accommodate gloves and standard probes as well.
Just keep the primary rule of no more than 1.5 inches apart for the best conduction and you'll have success!
Every client responds differently to an electric facial. Some clients prefer a tiny sensation, while others are happy with feeling nothing. The rule of thumb of microcurrent is one should not feel anything. Because the waveform reaches lower to the muscles, you many find several nerve triggers, this is can alarm you client so always start out lower and increase to you clients satisfaction.
Guidelines to follow:
Thin skin with little to no circulation 5-30
Thin skin with an impaired barrier 5-15
Medium skin with little to no circulation 30-55
Medium skin that is oily 30-75
Medium skin that is dehydrated and show signs of photo damage 30-55
Thick skin or face that has a thick subcutaneous fat layer 40-65
Thick skin that is oily 40-75
Thick photo damaged skin 50-75